Industrial Winterization for Hydrogen Plant Reliability: Best Practices to Implement This Year

Frozen-pipes-which-can-be-avoided-with-industrial-winterization-for-hydrogen-plants

The design and operation of a hydrogen plant can present unique challenges, and cold winter weather only makes things more difficult. As temperatures drop, hydrogen plants need to be prepared for the challenges posed by cold weather—especially in the Alberta winter.

Without effective industrial winterization practices at your hydrogen plant, you run the risk of serious safety hazards. Frozen pipes, condensation, and instrumentation failures can happen quickly and easily, leading to catastrophic failures. In this article, we’ll go over both pre-winter and post-winter best practices to prepare for cold weather and recommend resources to help you implement the best industrial winterization practices for your hydrogen plant.

Post-Winter: Incorporate Lessons Learned

Winterization of a hydrogen facility should start with a post-winter recap of lessons learned. Any challenges or incidents related to low temperatures and their impact on piping, equipment, and instrumentation should be evaluated to understand what went wrong and how they can be prevented in the future. Document the lessons learned and share the findings with all groups responsible for winterization practices.

In addition to lessons learned, proactively identify and address other potential freeze-related risks to piping and process equipment through process hazard analyses, management of change (MOC) evaluations, and safety and operating procedure reviews.

frozen-industrial-pipes

Based on risk analysis and lessons learned, establish formal, documented winterization procedures and update and train personnel to them yearly. A formal, written winterization program can help ensure nothing is missed when it’s time to prepare for next winter. Procedures should include winterization checklists specifying every step to prepare for cold weather. They should also include best practices for returning the plant to normal operations post-winter.

Your winterization strategies will be unique depending on the local climate and the equipment in the plant. Regardless of the conditions, it will likely need to address the following information:

  • Areas of high risk, such as those where sufficient insulation is not possible
  • Instructions for responding to temperature-related failures
  • Control points to be regularly monitored in addition to standard alarms and indicators
  • Water flow maintenance practices to prevent freezing
  • Heating area limitations of temporary heating equipment
  • Heat trace protection boundaries of equipment and systems
  • Lay-up procedures to protect idle equipment from freezing

Winterization procedures need to be tailored to the plant, so it is important to capture lessons learned each year post-winter and update the winterization plan as needed. Implementing these lessons will protect process equipment from cold temperatures, preventing serious incidents.

Pre-Winter: Best Practices

Ideally, winterization should begin in the late summer or early fall to allow plenty of time to identify and fix any potential issues. Thorough pre-winterization walk-downs of the entire plant should be conducted during this time. A standard winterization procedure with a checklist of important items is essential to ensure no potential hazard is missed.

Many of the necessary winterization activities will be unique to the location. Still, there are a few common best practices to consider:

  • Systematically review all process equipment, especially infrequently used piping and equipment—to identify and mitigate freezing hazards.
  • Identify equipment and piping susceptible to freezing and install appropriate types of protection:
    • End-of-line heat trace indicators on all piping susceptible to freezing
    • Remote monitoring of heat tracers from a dedicated display in the plant control room
    • Double insulation on piping or equipment where it might be needed
    • Anti-freezing additives where they are needed
  • Perform a heat trace and insulation audit to ensure winter readiness.
  • Erect wind barriers.
  • Replace damaged or unreliable equipment.
  • Remove or isolate dead legs from process streams or thoroughly insulate them if this is not possible.
  • Ensure there are adequate emergency generator backups and supplement them with portable backups.
  • Ensure lubricating oils used in the equipment are rated for winter temperatures in your area.

Heat tracing is essential to avoid frozen pipes, which can rupture. This includes piping in safety systems, such as fire protection systems and safety showers, which must always be operable. To ensure hydrogen plant safety, you should heat trace the water supply to these systems throughout the plant.

Winter temperatures vary considerably, and no equipment is designed to perform in all temperature conditions. When it comes to winterizing plant equipment, OEMs may not be able to provide an ideal or permanent solution for your plant’s specific winterization risks. When this is the case, look to other vendors who can help resolve inherent design issues and create a custom solution for your plant. Bringing in onsite field services will help your vendor identify risks and understand exactly what components or upgrades will provide the best reliability and protection.

Industrial Winterization for Hydrogen Plants

hydrogen-plantIndustrial winterization is not optional for hydrogen plants where winter temperatures drop to dangerous lows. Taking the appropriate measures to prevent cold weather-related incidents keeps your plant, your employees, and the environment safe.

Edmonton Valve & Fitting has been helping customers optimize and protect industrial fluid systems for over 50 years. Our experience positions us as an invaluable resource for Alberta’s growing hydrogen industry. Our expert Field Advisors are available for onsite or virtual consultations to help with risk analysis, leak detection, system optimization, component selection, and industrial winterization of hydrogen plants. Whatever your fluid handling needs, we have the expertise to help.

To find out more about how Edmonton Valve & Fitting can help perform industrial winterization for hydrogen plants, contact us through our website or by calling 780-437-0640.
edmonton-fugitive-emissions-plan-link

Fugitive Emissions Plan

Learn more about fugitive emissions, the root causes, and how to mitigate them.

More →

Field Advisory Services

Learn more about Field Advisory team and how they can help ensure the success of your pipelines. 

More →

View Locations

We serve northern and central Alberta from offices in Edmonton, Drayton Valley, and Fort McMurray.

More →

How can we help you today?

Whether you need a single component or help with complex systems, we are here to help.
Get in touch